Fractured Endo File? Don’t Panic… Bypassing Has a Solution!

Fractured Endo File? Don't Panic... Bypassing Has a Solution!

Click the image to enlarge it.

What Are We Talking About?

There are certainly those specific moments in our dental practices that send adrenaline levels skyrocketing. One of the most notorious among them is the “snap” sound or sensation you get while working with a rotary instrument, only to find the file coming out shorter than it went in. This moment of a separated instrument has been experienced by even the most skilled dentists and can honestly happen to any of us. The key isn’t to get flustered, but rather to know exactly how to react calmly and correctly to successfully navigate the situation and complete your treatment.

This article will serve as your essential guide, helping you understand the reasons behind file fractures so you can try to prevent them. More importantly, you’ll learn the detailed steps for the bypass protocol, enabling you to professionally salvage such situations.

Why Do Files Fracture in the First Place? Understanding Instrument Separation

Before we delve into the solutions, it’s crucial to grasp the root of the problem so we can proactively minimize its occurrence. Files don’t just break spontaneously; there’s always an underlying reason, usually one of the following:

1. Cyclic Fatigue (Repeated Stress from Use)

What Happens: Think of it simply like bending and straightening a metal wire repeatedly at the same point; eventually, it’s bound to break. The same phenomenon occurs with an endodontic file inside severely curved, or dilacerated, canals. Each rotation of the file within a curve imposes stress, and with numerous rotations, the metal weakens and ultimately snaps.

The Mistake: Using the same file for multiple cases, or even for a single case that involves particularly challenging canals, inevitably exhausts it.

The Right Way: These files are designed for single-use. Patient safety and your own peace of mind are far more important and valuable than the cost of a new file.

2. Torsional Stress (Excessive Force on the File)

What Happens: This occurs when the apex or tip of the file binds or “catches” firmly against a canal wall and can no longer rotate, yet the motor continues to spin, attempting to force its rotation. This action applies severe twisting (torsional) stress to the file until it fractures.

Common Mistakes Leading to Torsional Stress:

  • Incomplete Access: If your access cavity isn’t properly prepared to provide straight-line access, the file will enter the canal at an angle, making it highly susceptible to binding.

  • Excessive Apical Pressure: Rushing the process and applying too much manual pressure on the file to make it advance faster.

  • Not Using Instruments in Sequential Order: Skipping sizes, for instance, jumping directly from a size 15 to a much larger size 25, will cause the larger file to bind in a still-narrow canal, leading to fracture. It’s imperative to establish a clear glide path first.

  • Incorrect Motion: Rotary files require a gentle, brushing motion, not merely forceful apical pressure.

3. Absence of Sufficient Lubrication

What Happens: Working in a “dry” canal drastically increases friction between the file and the canal walls. This significantly raises the chance of the file binding and fracturing due to torsional stress.

The Mistake: Not using an adequate amount of a lubricating agent, such as EDTA gel or even copious Sodium Hypochlorite.

File Separated. What Now? The Bypass Protocol

So, it happened—the file fractured. Your first and most critical step: absolutely do not show any sign of panic. Take a deep breath and remain calm. The situation is still manageable.

Step 1: Assessment and Patient Communication

First, thoroughly irrigate the canal and halt all further procedures. Immediately take a periapical X-ray to precisely locate the fractured file. Determine if it’s in the coronal, middle, or apical third of the canal, and assess its relationship to any existing curvatures.

Next, you must calmly and professionally inform your patient to maintain their trust. You could use a phrase like:

“During the cleaning of your root canal, a very tiny tip of the delicate instrument we use separated inside. This is a known, occasional occurrence in very narrow canals, and please don’t worry at all. We have several effective ways to manage this situation, and we fully expect to complete your treatment successfully.”

Step 2: Preparing the Field for Bypass

Your immediate objective is to create a clear, straight path for a new file to smoothly navigate past the fractured segment.

  • Refine the Access Cavity: Ensure your access is perfectly optimized for straight-line access. Carefully remove any dentin shelves or obstructions that might cause the file to enter the canal at an angle.

  • Coronal Flaring: The coronal portion of the canal, superior to the fractured file, must be adequately flared. This provides better visibility and improved control. If you’re working with manual files, you can gradually use Gates Glidden Burs (starting with size 2, then 3). For rotary systems, use an Orifice Opener.

Step 3: Copious Irrigation and Lubrication

Generously fill the pulp chamber with EDTA gel. This gel will serve as an excellent lubricant, facilitating the easy passage of the new file, and will also help float out any dentin shavings that could block the path. Use Sodium Hypochlorite concurrently as an irrigant to help flush debris coronally.

Step 4: The Bypass Maneuver

This is where the precision work begins. Patience is the absolute key to success in this step.

  • Choose Your Instruments: Prepare small manual K-files, typically sizes 6, 8, and 10.

  • Pre-curve the File Tip: Create a gentle pre-curve in the last 2-3 mm of the file’s tip. This specific curvature will be your guide as you probe for space alongside the fractured instrument.

  • Begin the Maneuver:

    • Insert the smallest file (size 6 or 8) into the canal.

    • Crucially, do not apply heavy pressure. Use a very gentle watch-winding motion (a quarter turn clockwise, a quarter turn counter-clockwise) with minimal apical pressure.

    • Target the Space: Try to tactfully “feel” and explore for the patent space between the fractured file and the canal wall. This space is often found towards the inner aspect of the curve or along the buccal or lingual walls.

    • Patience and Repetition: You’ll likely find the file advancing a short distance and then stopping. Withdraw it, clean it, reapply EDTA, and try again. This process demands patience and precision, not force. (3)

  • Did the File “Pass”? Congratulations! The moment you feel the file tip advancing past the fractured segment, you’ve successfully achieved bypass.

  • Secure the New Path: After successfully bypassing with a size 8 file, start using a gentle up-and-down motion to incrementally widen this new pathway. Then, proceed with a size 10 file, repeating the same motion. You must at least reach a manual size 15 or 20 to establish a clear and confirmed glide path alongside the fractured instrument.

  • Continue Your Work: Once a proper glide path has been created, you can resume cleaning and shaping the canal with your rotary files as usual. The new files will follow the path you’ve established, with the fractured instrument remaining to the side.

Step 5: Final Obturation

When it’s time for obturation, you will proceed as normal. The fractured file will essentially become a part of the filling, encapsulated by gutta-percha and sealer. As long as you’ve effectively cleaned and disinfected the space around it and down to the apex, the prognosis for the case remains very high.

Important Final Notes

  • When to Attempt Removal vs. Bypass? The general rule of thumb is this: if the file fractured in the coronal or middle third of the canal and you can visually access it, attempts at ultrasonic removal might be a viable option. However, if it fractured in the apical third or beyond a severe curve, bypassing is usually the safer and more predictable solution. Attempting to remove a file from the apical third can lead to excessive dentin removal and significantly weaken the tooth structure.

  • File Fracture Isn’t a Sign of Inexperience: A file can even fracture in a seemingly easy and straight canal. Sometimes, there might be a manufacturing defect in the file itself, or an unexpected canal anatomy change not visible on radiographs. What truly matters is your composure and your ability to manage the situation effectively.

In conclusion, doctor, a fractured file isn’t the end of the world. It’s merely a challenge you’ll encounter in your daily practice. With calmness, knowledge, and the correct procedural steps, you can transform this difficult situation into a success story, proving your professionalism to both your patient and yourself.

Share this topic with your colleagues and anyone you think could benefit.

Interested in learning more? Check out the references!

  1. Vouzara, T., el Chares, M., & Lyroudia, K. (2018). Separated instrument in endodontics: Frequency, treatment and prognosis. Balkan Journal of Dental Medicine, 22(3), 123-132.

  2. Madarati, A. A., Hunter, M. J., & Dummer, P. M. H. (2013). Management of intracanal separated instruments. Journal of Endodontics, 39(5), 569–581.

  3. Zarekar, M. S., Satpute, A. S., & Zarekar, M. (2023). Management of Separated Instrument with File Bypass Method: Acquainting Two Case Reports. Asian Journal of Dental Sciences, 12(4), 25-29.

  4. Spili, P., Parashos, P., & Messer, H. H. (2005). The impact of instrument fracture on outcome of endodontic treatment. Journal of Endodontics, 31(12), 845-850.